Region West › Substation SS-047 › Overview
Protection Engineer
3
Active Feeders
12
Total Load
847 MW
Bus Voltage
138.2 kV
Frequency
50.02 Hz
Power Factor
0.96
THD
2.1 %
Faults Today
0
Protection Ops
0
Single-Line Diagram
All Breakers Normal
Main Bus — 138 kV
CB-01
T1
Feeder A
CB-02
T2
Feeder B
CB-03
T3
Feeder C
Breaker Status Matrix

Circuit Breaker Management

12 Breakers

Transformer Monitoring

Power Quality Analysis

2.1%
Voltage THD
3.4%
Current THD
0.96
Power Factor
0.8%
Voltage Unbalance
Harmonic Spectrum
Voltage Waveform
Power Quality Events
TimeTypePhaseMagnitudeDurationDescription
14:32:18SagA0.82 pu120 msVoltage sag on Phase A feeder F-03
12:15:04SwellB,C1.12 pu45 msOvervoltage on capacitor switching
09:47:33TransientAll1.8 pu2 msLightning-induced transient
08:22:11SagA,B0.91 pu80 msMotor start inrush on feeder F-07
06:05:44FlickerAllPst 0.910 minArc furnace load fluctuation
03:18:29SagC0.87 pu200 msDownstream fault on F-11
01:42:07HarmonicAllTHD 4.8%5 minVFD load causing 5th harmonic rise
00:11:55InterruptionAll0.0 pu350 msBreaker trip and auto-reclose

Fault Event Log

TimeTypeEquipmentPhaseFault I (kA)DurationProtectionCleared
Fault Statistics (12 Months)

Protection & Relay Management

12 IEDs ArmedIEC 61850 Ed.21 in Test
Active IEDs
12 / 13
Pickups (24h)
7
Trips (24h)
2
GOOSE Health
98.4 %
Protection Elements by Zone
ZoneElementANSIPickupTimeStatus
Z1 Bus ABus Differential87B0.20 puInstArmed
Z1 Bus AUndervoltage270.85 pu2.0 sArmed
Z2 Xfmr T1Xfmr Differential87T0.30 puInstArmed
Z2 Xfmr T1REF64REF0.10 puInstArmed
Z3 Feeder F-03Phase Overcurrent50/511.25 kA0.35 sPickup
Z3 Feeder F-03Ground Overcurrent50N/51N0.20 kA0.80 sArmed
Z3 Feeder F-07Distance (Mho)2180% Z1InstArmed
Z3 Feeder F-07Auto-Reclose793 shots1.5/5/15 sEnabled
Z4 IncomerDirectional OC671.50 kA0.25 sArmed
SystemUnder/Over Freq81U/O49.2 / 50.50.5 / 0.5 sArmed
Active Settings Group
Last change: 2026-04-14 by m.srdic • Verified by j.tanaka
Recent Pickup Ladder
14:31:58.01250F-03 Phase A overcurrent pickup (1.34 kA)
14:31:58.36251F-03 TOC trip, breaker CB-07 open
14:31:59.86279Auto-reclose shot 1 — success
09:47:33.00450NF-11 ground pickup, reset without trip
03:18:29.44127Bus A undervoltage pickup (0.83 pu)
Intelligent Electronic Devices (IEDs)
DeviceBayVendor / ModelFirmwareProtocolLast PickupStatus
IED-BUS-ABus ASEL-487BR133-V1IEC 61850 / GOOSEArmed
IED-BUS-BBus BSEL-487BR133-V1IEC 61850 / GOOSEArmed
IED-XFMR-T1T1 138/22 kVABB RET6702.2.5IEC 61850 / GOOSE2026-03-28Armed
IED-XFMR-T2T2 138/22 kVABB RET6702.2.5IEC 61850 / GOOSEArmed
IED-F-03Feeder F-03Siemens 7SJ85V9.30IEC 61850 / GOOSE14:31:58Pickup
IED-F-05Feeder F-05Siemens 7SJ85V9.30IEC 61850 / GOOSEArmed
IED-F-07Feeder F-07SEL-411LR320-V4IEC 61850 / GOOSEArmed
IED-F-09Feeder F-09Siemens 7SJ85V9.30IEC 61850 / GOOSEArmed
IED-F-11Feeder F-11SEL-411LR320-V4IEC 61850 / GOOSE09:47:33Armed
IED-F-12Feeder F-12Siemens 7SJ85V9.30IEC 61850 / GOOSETest Mode
IED-INC-1Incomer 1GE MiCOM P645B2.2.6IEC 61850 / GOOSEArmed
IED-INC-2Incomer 2GE MiCOM P645B2.2.6IEC 61850 / GOOSEArmed
IED-CAP-1Cap Bank 1SEL-451R218-V3IEC 61850 / GOOSEComms Loss
IEC 61850: Connected  •  Bay Controllers: 12/12  •  Protection: Armed
Confirm Switching Operation
Are you sure you want to toggle this breaker?